Split - core transformers TA_PV

This split-core current transformer can be found in the specialities section. It is intended for use with cable or PCB.
It incorporates a screw contact piercing system for the direct pick-up of the electrical signal from the cable or busbar.

This design allows the electrical signal to be picked up directly from the conductor or busbar, facilitating rapid installation without interruption of service or the need to disconnect the cable.

This split-core current transformer can be found in the specialities section. It is intended for use with cable or PCB.
It incorporates a screw contact piercing system for the direct pick-up of the electrical signal from the cable or busbar.

This design allows the electrical signal to be picked up directly from the conductor or busbar, facilitating rapid installation without interruption of service or the need to disconnect the cable.

 

Vampire


    BASIC DATA PROTECTION INFORMATION: Data controller: SOCIEDAD ANÓNIMA DE CONSTRUCCIONES INDUSTRIALES Purpose of processing: To manage the queries made and to send newsletters, commercial communications and promotions. Legitimisation of the processing: Legitimate interest and consent of the data subject. Retention of data: Data will be kept for as long as there is a mutual interest or for the time necessary to comply with legal obligations. Recipients: Service providers or collaborators. Rights: Right to withdraw consent at any time. Right of access, rectification, portability and deletion of your data and the right to limit or oppose its processing. Contact details for exercising your rights: info@saci.es Additional information: You can consult additional information in our Privacy Policy.

    Technical details

    • Dimensions
    • Technical characteristics
    • Technical data
    • Standards
    • Ratios

    Model / Cable
    TA40PV / Ø40
    TA60PV / Ø60
    TA80PV / Ø80

    • Window-type
    • Open core
    • For cable or busbar
    • Plastic enclosure
    • Easy installation due to the possibility to open the core
    • Secondary cable included for ease of installation

    Safety data

    • Accuracy: 0.5s
    • Continuous overload: 1.2 x In
    • Rated thermal short-circuit current: 60 x In or Ith limited by the dimensions of the primary busbar or cable
    • Rated dynamic current: 2,5 x Ith
    • Operating voltage (maximum): 720 VAC
    • Test voltage: 3 kV, 1 min.
    • Frequency: 50 - 60 Hz

    Additional information

    • Working temperature: -10ºC / +50ºC
    • Storage temperature: -25ºC to +75ºC.
    • Rated secondary I.: /5A
    • IEC 60185
    • UNE EN 618691 (IEC 618691)
    • UNE EN 618692 (IEC 618692)
    • VDE 0414
    • IEC60801-3.4
    • DIN 57414
    • BS 3938
    • EN 50081
    • EN 50082
    • IEC61010
    • UL94-V0