Reed frequency meters

Measurement of frequencies (50 or 60Hz) on alternating current lines around their nominal voltage value.

Measurement of frequencies (50 or 60Hz) on alternating current lines around their nominal voltage value.


    BASIC DATA PROTECTION INFORMATION: Data controller: SOCIEDAD ANÓNIMA DE CONSTRUCCIONES INDUSTRIALES Purpose of processing: To manage the queries made and to send newsletters, commercial communications and promotions. Legitimisation of the processing: Legitimate interest and consent of the data subject. Retention of data: Data will be kept for as long as there is a mutual interest or for the time necessary to comply with legal obligations. Recipients: Service providers or collaborators. Rights: Right to withdraw consent at any time. Right of access, rectification, portability and deletion of your data and the right to limit or oppose its processing. Contact details for exercising your rights: info@saci.es Additional information: You can consult additional information in our Privacy Policy.

    Technical details

    • Technical characteristics
    • Technical data

    Single Frequency Meter
    FC5V - 48x48mm - 0,23kg
    FC4V - 72x72mm - 0,39kg
    FC3V - 96x96mm - 0,47kg
    FC2V - 144x144mm - 0,88kg

    Double frequency meter
    FC3VI - 96x96mm - 0,84kg
    FC2VI - 144x144mm - 1,50kg

    Voltage range: ±15 % Vn
    Voltage (Vn): 100, 110, 230, 400, 440 V
    -Accuracy: 0,5 %
    -Own consumption: 1.2..2.2 VA. FC3VI, FC2VI: 2x (1,2...2,2 VA)

    Blades / scales (Hz):
    FC5V - Blades 7. Scales (Hz): 48,5..51,5 or 58,5..61,5
    FC4V - Plate 13. Scales (Hz): 47..53 or 57..63
    FC3V - Plate 13. Scales (Hz): 47..53 or 57..63. Scales (Hz): 46..54 or 56..64.
    FC2V - Plate 21. Scales (Hz): 45..55 or 55..65
    FC3VI - 2×17 blades. Scales (Hz): 46..64
    FC2VI - 2×21 blades. Scales (Hz): 45..65