ANG96 Network analyzer

The Network Analyser ANG96 is a device capable of measuring the variables associated with a power line. It receives the three current and three voltage signals from a four-wire network. It can also be used in three-wire networks, with connection to two three current transformers.

Description: The Network Analyser ANG96 is a device capable of measuring the variables associated with a power line. It receives the three current and three voltage signals from a four-wire network. It can also be used in three-wire networks, with connection to two three current transformers.


    BASIC DATA PROTECTION INFORMATION: Data controller: SOCIEDAD ANÓNIMA DE CONSTRUCCIONES INDUSTRIALES Purpose of processing: To manage the queries made and to send newsletters, commercial communications and promotions. Legitimisation of the processing: Legitimate interest and consent of the data subject. Retention of data: Data will be kept for as long as there is a mutual interest or for the time necessary to comply with legal obligations. Recipients: Service providers or collaborators. Rights: Right to withdraw consent at any time. Right of access, rectification, portability and deletion of your data and the right to limit or oppose its processing. Contact details for exercising your rights: info@saci.es Additional information: You can consult additional information in our Privacy Policy.

    Technical details

    • Connections
    • Dimensions
    • Technical characteristics
    • Technical data
    • Instrument DIN 96×96
    • 128×64 LCD display with feedback
    • Measured in 4 quadrants
    • Neutral current measurement
    • Harmonic Distortion (THD V and I)
    • Maximum demand (A, kW, kVA and kvar)
    • Maximum and minimum values
    • RMS voltage and current measurement
    • RS485 serial output
    • 2 built-in timers
    • TCP/IP (Optional: ANG96-TCP)
    • 4 timers (Optional: ANG96-G)

    ENTRANCE

    • Measuring range (Un): 0 - 520 V AC
    • Load: <1 mA per phase
    • Rated current (In): 1 and 5 A
    • Load: <0.3 VA per phase
    • Measuring range: 10 - 120% In
    • Frequency: 45 - 65 Hz
    • Overloads: 2 In permanent, 20 In 1s - 1.2 Vn permanent, 2 Vn 10s

    AUXILIARY VOLTAGE

    • Aux. V. Universal: 85 / 264 V AC; 80 / 300 V DC
    • Own consumption: <4 VA

    EXIT

    • Relays: 250 V AC 3A
    • Pulse width: 60 ms
    • Serial port: RS485
    • Protocol: Modbus RTU
    • Baud rate: Programmable, 1200 - 19200 bps / Standard 9600bps
    • 2-wire connection