TCIL2 Energy meter

The TCIL2 meter + analyser acts as an energy meter and measures the parameters of a three-phase or single-phase low-voltage network. It has RS 485 communication and the capacity to connect 32 devices on the same circuit or 128 via converter. Control can be done via computer or network from the device. It is also available with Ethernet port. Up to 6 electricity tariffs can be configured.

The TCIL2 meter + analyser acts as an energy meter and measures the parameters of a three-phase or single-phase low-voltage network. It has RS 485 communication and the capacity to connect 32 devices on the same circuit or 128 via converter. Control can be carried out via computer or network from the device.

Also available with Ethernet port. Up to 6 electricity tariffs can be configured.


    BASIC DATA PROTECTION INFORMATION: Data controller: SOCIEDAD ANÓNIMA DE CONSTRUCCIONES INDUSTRIALES Purpose of processing: To manage the queries made and to send newsletters, commercial communications and promotions. Legitimisation of the processing: Legitimate interest and consent of the data subject. Retention of data: Data will be kept for as long as there is a mutual interest or for the time necessary to comply with legal obligations. Recipients: Service providers or collaborators. Rights: Right to withdraw consent at any time. Right of access, rectification, portability and deletion of your data and the right to limit or oppose its processing. Contact details for exercising your rights: info@saci.es Additional information: You can consult additional information in our Privacy Policy.

    Technical details

    • Connections
    • Dimensions
    • Technical characteristics
    • Technical data
    • Versions

    Meter with the ability to reset the active energy meter, as well as perform a partial reset of the data.
    Modbus or Bacnet communications (programmable)
    Measuring quantities:

    • Consumption of a three-phase or single-phase network
    • Current
    • Voltage (Phase-Phase and Phase-Neutral)
    • Frequency
    • Power factor
    • Energy (imported and exported). Measured in the 4 quadrants
    • Active and reactive power (per phase and total)
    • Power quality analysis (THD V and I, harmonics up to 31, max. demand I, P, Q, S)

    Standards

    • EN 62053-21
    • EN 62053-22
    • EN 62053-23
    • DIN 43864
    • EN 61010

    VOLTAGE INPUT

    • Rated voltage: 3 x 230 / 400 V AC
    • Voltage measuring range: 63 to 276 Vpn AC
    • Frequency: 50 - 60 Hz
    • Network type: 1P2W, 3P3W and 3P4W

    CURRENT INPUT

    • Base current: 1.5 (6) A
    • Rated current: /5 or /1 programmable
    • Maximum current: 2 Inom
    • Current measuring range: 0 - 120% Inom
    • Starting current: 3 mA
    • Maximum self-consumption: < 0.1 VA
    • Continuous overload: 2 In
    • Instantaneous overload: 30 In 1s
    • Baud rate: 1200 - 19200 bps
    • Refill material: ABS, UL94 V0

    FOOD

    • Auxiliary voltage: Self-powered
    • Auxiliary voltage consumption: < 0.6 VA per phase

    TCIL2
    TCIL2 TCP
    TCIL2T
    TCIL2T TCP
    TCIL2 LP
    TCIL2 LP TCP