TUP_R Protection transformers with cable

Current transformers for protection aplications with built-in cable. These window-type transformers are generally used for PCB, although they can also be used with cable.

This transformer can be adapted to the specific requirements of each project, offering the possibility of configuring customised transformer ratios and electrical parameters, making it a flexible solution for multiple applications.

They are encapsulated in resin.

Current transformers for protection aplications with built-in cable. These window-type transformers are generally used for PCB, although they can also be used with cable.

This transformer can be adapted to the specific requirements of each project, offering the possibility of configuring customised transformer ratios and electrical parameters, making it a flexible solution for multiple applications.

They are encapsulated in resin.


    BASIC DATA PROTECTION INFORMATION: Data controller: SOCIEDAD ANÓNIMA DE CONSTRUCCIONES INDUSTRIALES Purpose of processing: To manage the queries made and to send newsletters, commercial communications and promotions. Legitimisation of the processing: Legitimate interest and consent of the data subject. Retention of data: Data will be kept for as long as there is a mutual interest or for the time necessary to comply with legal obligations. Recipients: Service providers or collaborators. Rights: Right to withdraw consent at any time. Right of access, rectification, portability and deletion of your data and the right to limit or oppose its processing. Contact details for exercising your rights: info@saci.es Additional information: You can consult additional information in our Privacy Policy.

    Technical details

    • Dimensions
    • Technical characteristics
    • Technical data
    • Standards
    • Ratios

    Model / Cable
    TUP85R / Ø85
    TUP140R / Ø140
    TUP150R / Ø150

    • Protection instrument
    • Window-type
    • Generally for busbar
    • Encapsulated in resin
    • Built-in cable

     

    General technical data

    • Factor of safety: Fs < 5
    • Operating voltage (maximum): 720 V
    • Test voltage: 3 kV AC (1min)
    • Frequency: 50-60 hz
    • Rated thermal short-circuit current: Ith limited by cable or primary busbar dimensions
    • Rated dynamic current: IDyn = 2,5 x Ith
    • Continuous overload: ID = 1.2 x IN
    • Operating temperature: -10 ... 50 ºC
    • Accuracy: 0.5 - 1 - 3 (0.2s; 0.2 and 0.5s on request)
    • Nominal secondary current: /5 or /1A
    • Insulation class: Class E // Class B (130 ºC) available
    • IEC 60185
    • UNE EN 618691 (IEC 618691)
    • UNE EN 618692 (IEC 618692)
    • VDE 0414
    • IEC60801-3.4
    • DIN 57414
    • BS 3938
    • EN 50081
    • EN 50082
    • IEC61010
    • UL94-V0

    Details of the product ratio table: