- Home
- Digital Instruments
- Programmable Digital Instruments
Programmable Digital Instruments
Categories: Digital Instruments
- User manual
- Certificate
- Software
Programmable indicators. Direct current. 3½ digits and 4 digits.
Measuring instruments complementing physical or electrical parameters converters.
- Technical features
- Technical data
- Versions
3½ Digits – Model DP35CP (96x48mm)
Ammeter. Rango de medida: 0 -1; 0 -5; 0 -10: 0 -20 ó 4-20 mA
Volmeter. Rango de medida: 0 -1; 0 -5; 0 -10: 1-0-1; 5-0-5; 10-0-10V; 1-5 ó 2-10V
4 Digits – Model DP46CPM (72x36mm)
Ammeter. Rango de medida: 0 -1; 0 -5; 0 -10: 0 -20 ó 4-20 mA
Volmeter. Rango de medida: 0 -1; 0 -5; 0 -10: 1-0-1; 5-0-5; 10-0-10V; 1-5 ó 2-10V
3½ digits – Model DP35CP (96x48mm)
-Optional programmable alarm.
-Keypad available to set the current and voltage transformer ratio (offset, end of scale and decimal point)
Display: Red led, digit height 14.3 mm, high luminosity.
Max. reading: ±1999
Accuracy: 0.2% of range ± 1 digit.
Overrange indication: OFL
Temperature coefficient: 0,01% / ºC
Auxiliary voltage: 110, 230 or 400 VAC ±20%.
Burden <3VA
Auxiliary voltage: 12, 24, 48, 110 or 220 VDC ± 20%.
Burden <2W
Alarm circuit: 1 potential free contact (250V, 3A, 200VA). Max. or Min. value OPTIONAL
4 digits – Model DP46CPM (72x36mm)
-Instantaneous, average and maximum value of the parameter.
-Programmable scale range through the keypad (offset, end of scale and decimal point).
-2 Maximum and Minimum programmable alarms available.Display: Red led, digit height 14.3 mm, high luminosity.
Max. reading: 9999; -999 (Split negative).
Accuracy: 0.2% of range ± 1 digit.
Overrange indication: OFL
Temperature coefficient: 0,01% / ºC
Auxiliary voltage: 110, 230VAC ±20%.
Burden <3VA
Auxiliary voltage: 12, 24, 48 or 110VDC ± 20%.
Burden <2W
Alarm circuit: 1 commutated potential-free contact (250V, 3A, 200VA). Max. and Min. value OPTIONAL
Units: mA – A – kA – mV – V – kV – rpm – % – m – Kg – bar – mm – kN – Hz – W – kW – mW – VA – var – kvar – mvar – kVA – ºC – ºF